Schneider Power Contactor 40A 3P 48V DC 1Z 1R EVK (LC1D40AED)

172,00 

Weight 1 kg

4 in stock

Planuojamas pristatymas: 5 December 2024 - 6 December 2024
Description

Power contactor 40A 3P 48V DC 1Z 1R EVK (LC1D40AED)

 

 

 

Description:

 

Range of productsTeSys D
Range of productsTeSys
Product nameTeSys D
Product or component typeContactor
The short name of the deviceLC1D
ApplicationResistive load
Motor control
Usage categoryAC-4
AC-3
AC-1
Number of poles3P
Contact combination3 NO
[Ue] rated operating voltage<= 300 V direct current (DC) for power circuit
<= 690 V alternating current (AC) 25…400 Hz for power circuit
[Ie] rated operating current40 A (<= 60 °C) at <= 440 V alternating current (AC) AC-3 for power circuit
60 A (<= 60 °C) at <= 440 V alternating current (AC) AC-1 for power circuit
Engine power in kW18.5 kW at 380…400 V AC 50/60 Hz AC-3
22 kW at 500 V AC 50/60 Hz AC-3
30 kW at 660…690 V AC 50/60 Hz AC-3
11 kW at 220…230 V AC 50/60 Hz AC-3
9 kW at 400 V AC 50/60 Hz AC-4
22 kW at 415…440 V AC 50/60 Hz AC-3
Engine power in HP5 HP at 230/240 V AC 50/60 Hz for 1 phase motors
10 HP at 230/240 V AC 50/60 Hz for 3 phase motors
30 HP at 575/600 V AC ( AC) 50/60 Hz for 3 phase
3 HP motors at 115 V alternating current (AC) 50/60 Hz for 1 phase
10 HP motors at 200/208 V alternating current (AC) 50/60 Hz for 3 phase
30 HP motors in 460/480 V alternating current (AC) 50/60 Hz for 3 phase motors
Type of control voltageDC STANDARD
Value of the control voltage48VDC
Built-in auxiliary contacts1 NO + 1 NC
[Uimp] rated impulse withstand voltageConforming to IEC 60947
Overvoltage categoryIII
[Ith] rated thermal current60 A at <= 60 °C for power circuit
10 A at <= 60 °C for signaling circuit
Irms rated switching current800 A at 440 V for power circuit according to IEC 60947
140 A alternating current (AC) for signaling circuit according to IEC 60947-5-1
250 A direct current (DC) for signaling circuit according to IEC 60947-5-1
Rated short circuit capacity800 A at 440 V for power circuit according to IEC 60947
[Icw] rated short-time withstand current100 A 1 s signaling circuit
120 A 500 ms signaling circuit
140 A 100 ms signaling circuit
320 A <= 40 °C 10 s power circuit
720 A <= 40 °C 1 s power circuit
72 A <= 40 °C 10 min. power circuit
165 A <= 40 °C 1 min. power circuit
Associated fuse ratings80 A gG at <= 690 V coordination type 1 for power circuit
80 A gG at <= 690 V coordination type 2 for power circuit
10 A gG for signaling circuit according to IEC 60947-5-1
Average impedance1.5 mΩ at 50 Hz – Ith 60 A for the power circuit
[Ui] rated insulation voltage600 V for power circuit CSA certificates
600 V for power circuit UL certificates
690 V for power circuit according to IEC 60947-4-1
690 V for signaling circuit according to IEC 60947-1
600 V for signaling circuit CSA certificates
600 V for signaling circuit UL certificates
Electrical durability1.5 Mcycles 40 A AC-3 at Ue <= 440 V
1.4 Mcycles 60 A AC-1 at Ue <= 440 V
Power loss per pole5.4W AC-1
2.4W AC-3
Protective coverWITH
Assembly methodRail
board
NormsCSA C22.2 No. 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
Product certificatesCCC
UL
GOST
CSA
Connections – terminalsControl circuits: screw terminals 2 cable(s) 1…2.5 mm² – cable stiffness: flexible – with cable end
Control circuits: screw terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuits: screw terminals 2 cable(s) 1…4 mm² – cable stiffness: flexible – without cable end
Control circuits: screw terminals 1 cable(s) 1…4 mm² – cable stiffness: flexible – with cable end
Control circuits: screw terminals 1 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Control circuits: screw terminals 2 cable(s) 1…4 mm² – cable stiffness: solid – without cable end
Power circuit : screw connection 2 cable(s) 1…25 mm² – cable stiffness: flexible – with cable end
Power circuit : screw connection 2 cable(s) 1…25 mm² – cable stiffness: solid – without cable end
Power circuit : screw connection 2 cable(s) 1…25 mm² – cable stiffness: flexible – without cable end
Power circuit : screw connection 1 cable(s) 1…35 mm² – cable stiffness: solid – without cable end
Power circuit : screw connection 1 cable(s) 1…35 mm² – cable stiffness: flexible – without cable end
Power circuit : screw connection 1 cable(s) 1…35 mm² – cable stiffness: flexible – with cable end
Tightening torqueControl circuits: 1.7 Nm – on screw terminals – with screwdriver flat Ø 6 mm
Control circuits: 1.7 Nm – on screw terminals – with Philips screwdriver no. 2
Power circuit: 5 Nm – on EverLink BTR screw connectors – cable <= 25 mm² hexagonal 4 mm
Power circuit: 8 Nm – on EverLink BTR screw connectors – cable 25…35 mm² hexagonal 4 mm
Working time16…24 ms opening
42.5…57.5 ms CLOSING
Level of security and reliabilityB10d = 1369863 contactor cycle with nominal load according to EN/ISO 13849-1
B10d = 20000000 contactor cycle with mechanical load according to EN/ISO 13849-1
Mechanical strength10 Mcycles
Connection frequency3600 cycles/h at <= 60 °C

 

Supplementary parameters

 

Coil technologyBuilt-in bidirectional suppression diode
Control voltage range0.1…0.3 Uc vanishing, cut-off at 60 °C, direct current (DC)
0.75…1.25 Uc operational at 60 °C, DC
Time constant34 ms
Power consumption attracting in W19 W at 20 °C
Power consumption holding in W7.4 W at 20 °C
Type of auxiliary contactsMechanically connected type (1 NO + 1 NC) according to IEC 60947-5-1
Mirror contact type (1 NC) according to IEC 60947-4-1
Frequency of the signaling circuit25…400 Hz
Minimum switching current5 mA for the signaling circuit
Minimum switch-off voltage17V for signaling circuit
Time without signals1.5 ms during switching off (between NC and NO contacts)
1.5 ms during switching on (between NC and NO contacts)
Insulation resistance> 10 MΩ for the signaling circuit
Motor power range AC-37…11 kW 200…240 V 3 phases
15…25 kW 380…440 V 3 phases
15…25 kW 480…500 V 3 phases
Motor starter typeDirect on-line contactor
Contactor coil voltage48V DC standard

 

Working environment

 

IP protection levelIP2x faceplate according to IEC 60529
Protective effectTH according to IEC 60068-2-30
Degree of pollution3
Ambient temperature for device operation-5…60 °C
Ambient temperature for storage-60…80 °C
Permissible ambient air temperature around the device-40…70 °C at Uc
Working altitude (in meters above sea level)3000 m without temperature derating
Fire resistance850 °C according to IEC 60695-2-1
FireproofV1 according to UL 94
Mechanical resistanceVibrations contactor open 2 Gn, 5…300 Hz
Vibrations contactor closed 4 Gn, 5…300 Hz
Shocks contactor open 10 Gn for 11 ms
Shocks contactor closed 15 Gn for 11 ms
Height122 mm
Width55mm
Depth120mm
Product weight0.925 kg